Overview
Assessment (PDF) sends the design from AutoCAD to the PVX.AI cloud for an energy yield calculation and returns a PDF report. The report covers DC and AC power, monthly climate and energy data, specific production, performance ratio, capacity factor and loss diagrams, with written commentary. A financial section and a battery (BESS) valuation can be added with two checkboxes in the same request.
Yield and financial analysis run from AutoCAD. The web viewer no longer offers them.
Prerequisites
- A design with racks, strings and a saved electrical configuration. Before it submits, PVX.AI checks the string sizing against the inverter voltage window, as PVsyst would.
- A license that includes Energy Yield Analysis. The assessment is a cloud job and uses credits.
Step-by-Step Guide
1. Open the request window
Open Export on the Export panel and choose Assessment (PDF). The Request Site Assessment window opens with two tabs: Request and Status & History.
2. Fill in the report details
On the Request tab, choose the Report language and Report currency, then enter the Report title and the Client. Both are required. The location, installed capacity and other cover page details come from the drawing.
3. Add the optional sections
- Tick Include financial analysis to add the cost, revenue, financing, degradation and schedule inputs. See Financial Analysis in Site Assessment.
- Tick Include BESS valuation to add a battery model. From placed BESS fills the battery fields from the BESS units in the drawing.
4. Submit the request
Click Request Analysis. PVX.AI writes the design as a PVCollada 2.0 file in the background and submits it. If the string sizing breaks the inverter voltage window, the request is blocked and the problem strings are listed. If it only raises PVsyst warnings, you can submit anyway or go back.
5. Track the job and download the PDF
Open Status & History. Previous analyses lists every request with its status. Use Refresh to update the list, Download PDF when a job completes, View log to see why a job failed, Retry to run a failed job again, and Reuse to copy a past request’s inputs back to the Request tab.
Tips & Recommendations
- Use Reuse to run a variant of an earlier assessment (a different module, a different tariff) without typing the inputs again.
- Run Health Check on the Design Review panel before you request an assessment. Strings without a transformer or devices that were moved but not adapted give a report that does not match the drawing.
- The assessment reads the drawing at the moment you click Request Analysis. Request a new one after design changes.
- For a PVsyst project file of your own, export with Design (PVC) or Design (PVC 2.0) instead.