Overview
Import PVcase Design reads the PVcase data inside the drawing that is open and rebuilds it as native PVX.AI objects. After the import, the project works like one designed in PVX.AI: you can regrade it, adapt the terrain to the piles, change the electrical design and export it.
PVX.AI reads PVcase designs from a DWG (or DXF) exported or saved by PVcase. PVcase project files (.pvk) are not supported.
Prerequisites
- The PVcase DWG open in AutoCAD. There is no file picker: the import scans the current drawing.
- A licensed PVX.AI installation. The import runs on your computer and does not use credits.
Step-by-Step Guide
1. Run the import
On the Layout panel, open Import and click Import PVcase Design. PVX.AI first lists on the command line what it found: areas, frames, strings, combiner boxes, inverters, transformers, cables, exclusions and trees.
2. Let the units settle
The drawing’s units are set to match the PVcase project: a metre project gives a metre drawing, a foot project a feet drawing. A drawing already set to US survey feet is kept as it is. The command line says which units were set. PVcase lengths are converted on import, so feet projects come in at their true size.
3. Check what was converted
- PV areas from the PVcase areas, with their PVcase names.
- Terrain, rebuilt as a PVX.AI terrain grid per area from the PVcase mesh or topography data.
- Racks: fixed, tracker and East-West frames, with the matching rack specs created. Split terrain-following tracker parts are joined back into one tracker and settled on the imported terrain.
- True tracker lengths: PVcase’s half-gaps are added back and its pile overhang becomes the tube extension, so a tracker keeps its PVcase length.
- Piles from the pile schedule PVcase stored for each frame. If a frame has no usable schedule, that rack is imported with no piles and the command line warns you. PVX.AI does not invent a pile layout.
- Electrical: strings, DC combiner boxes, string and central inverters, transformers, string, DC and AC cables, and trenches, with their PVcase IDs. Cable lengths are stored correctly in feet drawings.
- Exclusions from the PVcase offsets, trees as PVX.AI tree shading objects, roads from their centrelines, and stations and fences as shading objects.
- Georeference from the drawing’s geolocation or the PVcase location settings. If neither is usable, the command line asks you to set a location.
4. Compare with the original
The PVcase entities are not changed. Their layers are turned off and frozen after the import; thaw them to compare the original with the converted objects. Pile-length labels are added at the end.
5. Continue the design in PVX.AI
Run Health Check to spot anything that needs attention, then continue with grading, Adapt Terrain to Pile or the electrical tools as on any PVX.AI design.
Tips & Recommendations
- Not imported: multi-row tracker groups (each row becomes its own rack), harness and trunk DC layouts, AC combiners, HV cables, BESS, grading pads and proposed grade, wind turbines and pylons (their keep-out areas come in as exclusions), and PVcase’s per-part tracker heights (PVX.AI settles trackers on the terrain itself).
- Import once. Running the import again on the same drawing adds a second copy of everything. To start over, undo: from the ribbon it takes two Ctrl+Z, the first removes the overview outlines and the second the import.
- PVcase projects in millimetres or inches cannot be matched to drawing units. Rigid racks and the electrical design still import, but the terrain and terrain-following trackers are skipped, with a warning.
- If you imported a PVcase design into a feet drawing with a version older than 2.11.0, import it again: cable lengths and some object sizes were wrong in older versions.
- Frames outside every PV area are placed but not assigned to an area. Check them after the import.
- Before switching tools for good, see Moving from PVcase.