Defining PV Areas

Overview

A PV area is the closed boundary inside which PVX.AI places racks. Build Layout, Capacity Iteration, Import Layout, Adapt Objects, the corridor pattern and the electrical design all work per PV area, so every project starts here. You can draw a PV area by picking points, or convert a boundary that is already in the drawing.


Prerequisites

A drawing open in AutoCAD or Civil 3D with PVX.AI loaded. To convert a boundary, it must be in the drawing, for example from Import KML/KMZ or a survey. Terrain is not needed to define the area, but Build Layout uses it later for slope checks and 3D placement.

Step-by-Step Guide

1. Open the Area dropdown

On the PVX.AI ribbon tab, go to the Site Layout panel. Clicking the face of the Area button starts Draw PV Area. The arrow opens the full list: Draw PV Area, Convert PV Area, Draw BESS Area and Convert BESS Area. BESS areas are battery zones; Build Layout never places racks inside them.

2. Draw a PV area

Choose Draw PV Area and pick the corners of the area in the drawing. Type U (Undo) to remove the last point. Once you have at least three points, press Enter, press Escape or type C (Close). The polygon is closed for you.

3. Or convert an existing boundary

Choose Convert PV Area and select the boundary: a polyline, circle or hatch. You can select several boundaries at once, and each becomes its own PV area. A polyline whose ends do not quite meet is closed for you; read the command line for a note on any gap that was closed.

4. Leave a working margin

If the parcel line is the legal boundary, offset it inward with the AutoCAD OFFSET command by the setback your project requires and convert the offset copy. If you want a perimeter road, do not draw it into the PV area by hand: switch on Boundary Road in Build Layout, which rings each PV area with a road of the width and setback you enter.

5. Check the name

Each PV area gets a sequential name (PV-1, PV-2 and so on). The name is used in the Build Layout boundary list, the electrical design, the BoQ and the exports. Device numbers in a new PV area continue after the numbers other PV areas already use.


Tips & Recommendations

  • A drawing can hold several PV areas. Build Layout and Capacity Iteration can work on many of them in one run.
  • Mark buildings, ponds and other obstacles inside a PV area as exclusion areas instead of cutting holes in the boundary.
  • A PV area stores its own corridor pattern. Erasing the PV area erases the pattern with it, and Ctrl+Z brings both back.
  • If a layout command finds no PV area, check that the boundary was converted with Convert PV Area and is not just a plain polyline.