Defining Exclusion Areas

Overview

An exclusion area is a closed zone where no racks may stand: a building, a pond, a protected tree group, a power line corridor. Build Layout, Capacity Iteration, Import Layout and Move Racks all keep racks out of exclusion areas. For a battery storage zone, use a BESS area instead; it is excluded the same way and is also used by the BESS Designer.


Prerequisites

A PV area. To convert an obstacle, its outline must be in the drawing as a polyline, circle or hatch.

Step-by-Step Guide

1. Open the Exclusion dropdown

On the Site Layout panel, clicking the face of the Exclusion button starts Draw Exclusion Area. The arrow also lists Convert to Exclusion Area.

2. Draw an exclusion area

Choose Draw Exclusion Area and pick the corners of the zone. Type U to remove the last point. With at least three points, press Enter, press Escape or type C to close it.

3. Or convert existing outlines

Choose Convert to Exclusion Area and select one or more outlines, for example building footprints from a survey. Each outline becomes its own exclusion area.

4. Include the clearance you need

An exclusion area is a hard limit: a rack that touches it is not placed. Draw it at the size of the obstacle plus the clearance your project requires. A quick way is to offset the obstacle outline with OFFSET and convert the offset copy.

5. Build or rebuild the layout

Exclusion areas are read when the layout is built. If racks are already placed in the PV area, run Build Layout again for it. Move Racks also refuses to drop a rack inside an exclusion area and says so on the command line.


Tips & Recommendations

  • With the Draw Alignment placement direction, an exclusion area removes only the tables it covers; the rest of the row keeps its spacing.
  • For steep ground, use the slope limits in Build Layout rather than drawing exclusion areas by hand.
  • A wind turbine added as a 3D scene object has its own exclusion radius around the blade tips where no panels are placed.