Fixed Distance PV Layout

Overview

Build Layout fills one or more PV areas with racks at a constant row pitch. It works for fixed-tilt, east-west and tracker racks. Use a fixed pitch when the row spacing is given (by a GCR, a maintenance vehicle or a client specification). If you want the spacing to follow the sun angle and the terrain slope instead, use Dynamic Pitch, described in the Dynamic Distance PV Layout guide.


Prerequisites

At least one rack type under Database > Products > Racks, at least one PV area, and terrain if you want slope checks and 3D placement.

Step-by-Step Guide

1. Open Build Layout

On the Layout panel of the PVX.AI ribbon tab, click Build Layout. The Layout window opens.

2. Select the racks

Click Select Rack and choose the rack type. You can choose more than one type of the same kind (hold Ctrl): PVX.AI places the first type and fills leftover space with the next one, which reduces empty strips at the area edges.

3. Choose the placement direction

Placement Direction decides where rows start and therefore where leftover space ends up:

  • Left To Right / Right To Left (fixed) and Bottom To Top / Top To Bottom (trackers): rows start at one edge of the PV area.
  • Center Grid: a grid laid out for corridors and service roads.
  • Draw Alignment: you draw a line per PV area (or reuse a stored one: Use, Redraw or Cancel) and racks fill outward from it on both sides. When the line runs on a road, both sides start at the road edge plus its rack setback. Fixed racks follow the north-south parts of the line, trackers the east-west parts.

4. Select the PV areas

Click Select Boundaries and pick one or more PV areas. They are listed in the window; click the cross next to a name to drop one, or Remove All to start again.

5. Set the terrain slope limits

Switch on Use 3D Terrain (Slope Checking) and enter the limits in percent: N (%) and S (%) for north and south facing slopes, EW (%) for east-west slope. Racks whose ground exceeds a limit are not placed. Take the limits from the rack manufacturer.

6. Set the spacing

In the Build section enter the Pitch Distance: the distance between the same point on two neighbouring rows. Distance Between Racks has two boxes: the gap between rows and the gap between tables in a row. For fixed racks the pitch and the row gap stay in step (pitch = rack depth + row gap), so you can type either one. For trackers, the pitch is the distance between tracker axes. Azimuth Offset (°) rotates the rows; the window shows the result as the base azimuth (180° in the northern hemisphere) plus your offset.

7. Add corridors and a boundary road (optional)

In the Corridor section, switch Enable on and click Edit corridor… to set where service roads and open gaps split the rack blocks. In the Boundary Road section, switch Enable on and set its Width and Setback to ring each PV area with a perimeter road.

8. Build

Click Build. PVX.AI places racks PV area by PV area. If you cancel, finished PV areas are kept and the rest are cleared. A new layout replaces racks, and their electrical design, only in the PV areas it builds.


Tips & Recommendations

  • Not sure which pitch gives your target capacity? Click Capacity Iteration at the bottom of the window to compare spacings before you build.
  • Gaps in steep zones are expected: they are where the ground exceeds the rack slope limits.
  • In a feet drawing every length box is shown and entered in feet.
  • After building, run Collision Analysis to check pile reveals and ground clearance.

Related