Running a Design Health Check

Overview

Health Check is a read-only scan of the whole drawing. It runs a set of rules over boundaries, terrain, racks, roads and the electrical design, gives a score from 0 to 100 with a grade, and lists each finding with a way to zoom to it. It never changes the drawing, so you can run it at any stage.


Prerequisites

A drawing with design data in it. Health Check reports “No design data found in this drawing.” on an empty one.

Step-by-Step Guide

1. Run the scan

Click Health Check in the Design Review panel of the PVX.AI ribbon, then Rescan. The status line shows when the last scan ran, how long it took, how many rules were checked, and the grade.

2. Work through the findings

Findings are grouped by ribbon area. Each one has a severity (critical, warning or info) and a Zoom action that jumps to the objects involved. An area with nothing to report reads all checks passed.

3. Electrical checks

  • EL1 Orphan strings: strings with no inverter or DC combiner they can be traced to.
  • EL2 Stale DC cable lengths: DC cable lengths that no longer match the drawn cables. Regenerate cabling.
  • EL3 Electrical devices missing back-references: devices with a missing or broken link back to the design.
  • EL4 Configured devices not placed: devices in the saved plan that are not in the drawing. Run Place Devices again.
  • EL5 Devices moved but not adapted: inverter, transformer or DC box blocks moved or rotated with AutoCAD, so their stored position is out of date. Run Adapt Devices. EL5 also reports Copied device blocks: copies share another device’s identity and are not part of the design, so delete them or place a new device.

4. Rescan after edits

Fix what you can, then click Rescan. If you switch drawings, the window tells you the findings are out of date until you rescan.

5. Export the report

Click HTML report… to save a report you can open in a browser, or Findings CSV… for a spreadsheet of every finding. Both work as a design-review record for handoff or QA.


Tips & Recommendations

  • Run it before sending a drawing to a client, before exporting, and before generating the SLD.
  • Other rules cover PV area boundaries (overlaps, degenerate or unconverted ones), terrain (invalid grid, missing georeference), racks (outside the boundary, overlapping, missing data), roads, project settings and drawing units.
  • Health Check counts every PV area of the drawing, not only the active one.

Related