Creating Fixed Racks: Simple Design

Overview

A fixed rack in PVX.AI is a table of modules at one tilt angle, standing on a grid of piles. In the simple workflow the Rack Design block stays in Automatic mode: you give the number of piles and their spacing, and PVX.AI places them evenly and works out the overhangs. Use this for standard tables. If you have a vendor drawing with uneven pile spacing, use the detailed design instead.


Prerequisites

The PV module you want to use, either from the catalog or created as a custom module.

Step-by-Step Guide

1. Open Fixed Settings

Go to Database > Products > Racks. The Racks window lists your Fixed Racks and Tracker Racks. Click Create Fixed to open Fixed Settings.

2. Select the module

Click Select Module and pick the module. The table dimensions are calculated from its size, so choose the module first.

3. Set the Basic Design

  • Name: the name you will pick in Build Layout and see in reports.
  • Pile Profile: SHS (Square Hollow Section), C-Channel, I-Beam or U-Channel. Match the steel you will procure.
  • Default Color: how the rack is drawn.
  • Module Orientation: portrait or landscape.
  • Angle (°): the tilt of the table.
  • Columns and Rows: modules across the table width and module rows up the table. A 2-high portrait table of 28 modules is 14 columns by 2 rows.

4. Set module spacing

In Module Place Design, set Vertical Spacing (gap between module rows, up the slope of the table) and Horizontal Spacing (gap between modules side by side). Use the clamp gap from the mounting system datasheet.

5. Set the piles and heights

The block header reads Rack Design (Automatic). Set Number of Pile Rows (piles front to back), Number of Piles (piles along the table) and Distance Between Piles. PVX.AI centres the piles and shows the resulting Distance to Front Pile, Distance to Back Pile, Overhang Left and Overhang Right as read-only values.

Then set Height Bottom, the height of the table’s low (front) edge above the ground. Height Top is calculated from it, the tilt and the table depth. Set Underground Pile Depth to the embedment length.

6. East-west tables (optional)

For an east-west (dome) system, tick East-West (Dome) and set the Ridge Gap between the two halves.

7. Save

Click Save. The rack appears under Fixed Racks and can be used in any layout.


Tips & Recommendations

  • Height Bottom is a design value on flat ground. On real terrain the actual clearance and pile lengths vary; check them with Collision Analysis after placement.
  • Click Automatic in the block header to switch to Manual when the pile spacing is not uniform. The settings you entered are kept as the starting point.
  • Library racks are read-only. To change one, select it in the Racks window and use Clone to save your own copy.
  • Use Export and Import .pvxrack file in the Racks window to share rack specs with colleagues, or Import from drawing to add the racks used in an open drawing to your library.

Related