Overview
Stringing connects modules in series and draws the positive (+) and negative (-) ends of each string. In PVX.AI it is preset-driven: you save a stringing preset for a rack type once, then apply it to every rack of that type in a PV area, or to racks you pick. Stringing is step 1 of the five steps in the Electrical Design window: Stringing, Scope, Configure, Place Devices, and Trenches & Cabling.
Stringing decides which modules form a string. How many strings go to each inverter is decided later, in the Configuration Panel.
Prerequisites
- Racks placed inside a PV area.
- The module datasheet values (Vmpp, Voc, Impp, power) and the inverter’s maximum DC voltage.
Step-by-Step Guide
1. Open the Electrical Design window
On the PVX.AI ribbon, click Electrical to open the Electrical sub-tab, then click Electrical Design. The window opens on step 1, Stringing.
2. Create a preset and choose the stringing type
Click Create Preset (or New once presets exist) to open the Stringing Setup window. Pick the Stringing Type:
- Single Row: each string runs along one module row.
- U-Stringing: the string runs out along one row and back along the next, so both ends finish at the same end of the table.
- Leap Frog: a zigzag pattern suited to longer tables.
- Custom: you draw the strings yourself in the Custom Stringing Editor. See Custom Stringing Options.
3. Set direction and electrical data
Set Direction to Left to Right or Right to Left, toward the side where the inverters or DC boxes will stand. Enter the Module Parameters (Vmpp, Voc, Impp, Power) and the Inverter / System Parameters: Max System Voltage (V), default 1500, and Inverter Vmax (V), default 1100. The window shows the string size and its valid range as you type, for example “String size: 26 modules (range: 24-30)”. Adjust Modules per String to stay inside that range.
4. Save the preset
Pick the Application Mode: Single Rack strings one rack, String Area applies the preset to every compatible rack in a PV area boundary, and String Frames applies it to racks you pick one by one. Click Save as Preset. Each preset remembers the rack type it was made for. To capture the pattern of a rack that is already strung, use Create from Frame.
5. Apply the preset
Select the preset in the dropdown of step 1, then:
- Apply to Boundary: select a PV area boundary. Every rack of the preset’s rack type inside it is strung.
- Apply to Selection: pick racks in the drawing. While the panel is working, racks show as cyan outlines; you can click those outlines. Only the preset selected in the dropdown is applied. Racks of another rack type, or racks that are already strung, are skipped, and a summary tells you what was strung and what was skipped.
6. Fix strings that came out wrong
In the Stringing Setup window, String Tools holds Destring (delete the selected strings), Mirror Strings (reverse their direction) and Reverse Polarity (swap the + and – ends). The Strings menu on the Electrical sub-tab has Mirror Strings, Clear Selected Strings and Clear All Strings. On a drawing with two or more PV areas, Clear All Strings asks whether to act on PV areas you pick or on the whole drawing. Racks always stay.
Tips & Recommendations
- Point the direction toward the device side. It keeps home-run cables short.
- String numbers (STR labels) are given when devices are placed, following the rows. The order is set in the Configuration Panel under String numbering: Top to bottom or Bottom to top.
- Every PV area is its own electrical unit, so a multi-area site can be strung one area at a time.
- Mirror Strings leaves strings built with Pick modules (one by one) as drawn. Delete and pick them again instead.
