Setting Up Terrain-Following Trackers

Overview

A terrain-following tracker (TFT) is a chain of rigid segments joined by articulation joints, so the row can bend to follow the ground instead of sitting on one straight line. On rolling sites this reduces grading and keeps pile reveals more even. PVX.AI places each frame on the real terrain and checks it against the mechanical limits you enter in the spec. This guide covers building that spec.


Prerequisites

A PV module in the database and the tracker vendor’s data: joint count, joint articulation limit, piles per segment and tube dimensions.

Step-by-Step Guide

1. Create the tracker

Go to Database > Products > Racks, click Create Tracker and pick the Terrain Following card. Tracker Settings opens with an extra Terrain Following section. Select the module and fill in the Basic Design as for any tracker.

2. Define the joints and segments

  • Joint Gap Count: number of articulation joints along the tube. Zero would make it a rigid tracker.
  • Joint Gap Size: the module-free gap at each joint (default 1.0 m).
  • Segment Distribution: modules per segment. Click Edit… to set uneven segments; this decides where each break falls along the tube.

3. Set the piles

Choose Piles per Segment (default 2), Place piles at joints, and Add pile at each break (motor pier) if the vendor puts a pier under the motor. With 2 piles per segment every pile sits on the segment’s straight line; use 3 or more if you want each pile’s reveal to follow the ground individually. For a vendor layout with uneven spans, switch the Rack Design block to Manual and use Pile Schedule.

4. Enter the mechanical constraints

Open Mechanical Constraints. Values are entered as percent slope and the degree equivalent is shown live. Only the first is required:

  • Segment Break Angle (%): the largest slope change allowed at one joint. The default is about 3.49 % (2°), a conservative value; use the vendor’s figure.
  • Rigid drive connection (no hinge at motor): tick it if the two segments either side of the motor are joined rigidly.
  • Motor Hinge Angle (%): an optional, tighter limit at the motor joint. It does not apply when the drive connection is rigid.
  • Wing Total Slope (%) and Segment Slope (%): optional limits on the whole wing and on any single segment.
  • Min Ground Clearance, Max Ground Clearance, Min Pile Reveal, Max Pile Reveal: optional bands checked after the frame settles. See Validating a Terrain-Following Tracker Design.

5. Torque tube and height

Tick Model torque tube and enter Diameter, Top Gap and Bottom Gap. Set Reference Height (default 0.500 m): the lowest frame edge above perfectly flat ground. The form shows the above-ground pile length it implies. Reference Height is not a minimum clearance; real clearance is checked by the ground clearance band. Click Save.


Tips & Recommendations

  • Every field has an info icon that explains what it controls.
  • A terrain-following tracker cannot carry the motor at the very end of the chain; place it between modules.
  • If tables are driven in groups by one motor, tick Multi-row trackers in the same section. See Multi-Row Tracker Groups.
  • Terrain-following designs can be mirrored, and imperial (feet) drawings are supported.